ENDOUROLOGY - Original Article

Can magnitip double-J stent serve as a substitute for a standard double-J stent?

Volume 45 · Issue 6 Publish Date: October 11, 2019
Full Text PDF
DOI
Wael A. Maged
Department of Urology, Ain Shams University Faculty of Medicine, Cairo, Egypt
Mohamed Hasan
Department of Urology, Ain Shams University Faculty of Medicine, Cairo, Egypt
Ahmed Farouk
Department of Urology, Ain Shams University Faculty of Medicine, Cairo, Egypt
Ahmed Tawfick
Department of Urology, Ain Shams University Faculty of Medicine, Cairo, Egypt
Abdulwahab A. Abuftira
Department of Urology, Ain Shams University Faculty of Medicine, Cairo, Egypt
Maged, W. A., Hasan, M., Farouk, A., Tawfick, A., & Abuftira, A. A. (2019). Can magnitip double-J stent serve as a substitute for a standard double-J stent?. Urology Research and Practice, 45(6), 437–443. https://doi.org/10.5152/tud.2019.19038
Full Text Full Text PDF

Abstract

Objective: To evaluate the morbidity of the magnitip double-J stent (DJ), compare its morbidity to the standard stent, and evaluate the possibility of retrieving the magnetic tip of the DJ stent without cystoscopy.

Material and methods: A total of 50 patients having a lower ureteric stone, who underwent uretroscopic stone retrieval and required the use of a DJ, were randomly assigned to 2 groups, each containing 25 patients. Patients in group A were subjected to exploration with a uretroscope and a magnitip DJ while those in group B received a uretroscope and a standard DJ. The morbidity of both types of DJs was assessed by the Arabic version of the ureteral stent symptom questionnaire (USSQ).

Results: There was a high level of statistically significant differences between the two groups with regards to the total score of the USSQ, which were higher in group A as compared to group B (126.96±14.76 vs. 98.24±12.9) (p=0.001). Further, the cost of the total procedure was significantly higher in group B (9600±1456.59 vs. 8444±783.73) (p=0.001). No statistically significant difference was found between both groups regarding the application, retrieval accuracy, and discomfort caused by DJ removal.

Conclusion: The morbidity caused by the magnetic DJ was found to be higher. However, the removal of the magnetic DJ was less costly than the standard DJ.

Cite this article as: Farouk A, Tawfick A, Hasan M, Abuftira AA, Maged WA. Can magnitip double-J stent serve as a substitute for a standard double-J stent? Turk J Urol 2019; 45(6): 437-43.

Similar Articles

Article Info
Published In
Journal Urology Research and Practice
Volume / Issue Volume 45 · Issue 6
Pages 437-443
History
Published Online October 11, 2019
Copyright
Affiliations
Wael A. Maged
Department of Urology, Ain Shams University Faculty of Medicine, Cairo, Egypt
Mohamed Hasan
Department of Urology, Ain Shams University Faculty of Medicine, Cairo, Egypt
Ahmed Farouk
Department of Urology, Ain Shams University Faculty of Medicine, Cairo, Egypt
Ahmed Tawfick
Department of Urology, Ain Shams University Faculty of Medicine, Cairo, Egypt
Abdulwahab A. Abuftira
Department of Urology, Ain Shams University Faculty of Medicine, Cairo, Egypt
Cite this Article
Maged, W. A., Hasan, M., Farouk, A., Tawfick, A., & Abuftira, A. A. (2019). Can magnitip double-J stent serve as a substitute for a standard double-J stent?. Urology Research and Practice, 45(6), 437–443. https://doi.org/10.5152/tud.2019.19038
Outlines